E5
V-ZUG
Power Management / Load Limitation Error
Induction hob shows E5 and may limit maximum power.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect power management configuration, Faulty power management sensor, Software misconfiguration after installation, Main board fault
How to Fix / Troubleshooting
User actions:
- Disconnect power for 1–2 minutes and reconnect to reset the electronics.
- If the hob has a user-accessible power management setting (see manual), verify that it is set correctly for your electrical installation.
Technician actions:
- Enter service mode (per V-ZUG documentation) and check the configured maximum power and phase configuration.
- Correct any misconfiguration and store settings.
- If E5 persists, replace the main control board.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control Board
Check Price on Amazon