F07
Viking Relay Board / Power Relay Failure

Viking oven shows F07 and will not start; sometimes accompanied by a beeping alarm.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed power relay on relay board, Burnt solder joints on relay board, Overheated wiring at relay terminals, Internal short in heating element causing relay damage

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker. High voltages are present on the relay board; do not work with power on.

Steps to check and correct:

  • Access relay board: Remove the rear panel or lower front panel (depending on model) to locate the relay board that controls the bake and broil elements.
  • Inspect wiring: Look for burnt or discolored wires at the relay terminals. Repair or replace any damaged wiring and terminals.
  • Check for burnt relays: Examine the relay board for darkened areas, cracked solder joints, or melted relay cases. These are signs of failure.
  • Test heating elements: Before replacing the relay board, disconnect and test the bake and broil elements for shorts to ground using a multimeter. A shorted element can cause relay failure.
  • Replace relay board: If relays are visibly damaged or F07 persists after wiring checks, replace the relay board with the correct Viking part number.

When to call a technician: Because this repair involves high-voltage circuits and board-level components, it is often best handled by a qualified technician.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Oven Relay Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements