Display shows AL07 and the appliance may not cool or may show erratic compressor behavior.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Unplug the refrigerator. Do not attempt to open the sealed system.
Checks:
- Ensure adequate ventilation around the appliance; move it away from walls if necessary.
- Remove the rear lower cover and inspect the compressor and inverter module for burn marks or a burnt smell.
- Check that the condenser fan is running freely and not obstructed.
Next steps: If the inverter module is visibly damaged, it should be replaced. If AL07 persists after inverter replacement, the compressor or main control board may be faulty. These repairs require a licensed technician.
Repair Difficulty
Required Part
We may earn a commission from links on this page.