AL07
AEG Compressor / Inverter Alarm

Display shows AL07 and the appliance may not cool or may show erratic compressor behavior.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty inverter module, Overheated compressor, Seized compressor, Faulty main control board output

How to Fix / Troubleshooting

Safety first: Unplug the refrigerator. Do not attempt to open the sealed system.

Checks:

  • Ensure adequate ventilation around the appliance; move it away from walls if necessary.
  • Remove the rear lower cover and inspect the compressor and inverter module for burn marks or a burnt smell.
  • Check that the condenser fan is running freely and not obstructed.

Next steps: If the inverter module is visibly damaged, it should be replaced. If AL07 persists after inverter replacement, the compressor or main control board may be faulty. These repairs require a licensed technician.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor Inverter Module
Check Price on Amazon

We may earn a commission from links on this page.