E6
AEG Communication Error Between Display Board and Main Control Board

Display shows E6 and the refrigerator may not cool or may behave erratically.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose or damaged communication harness, Oxidized connectors, Faulty display PCB, Faulty main control PCB

How to Fix / Troubleshooting

Safety first: Unplug the refrigerator before removing any covers or touching wiring.

Basic reset:

  • Disconnect power for 10–15 minutes to fully discharge the electronics, then reconnect. If E6 clears and does not return, it may have been a transient glitch.

Harness and board checks:

  • Remove the display/control panel and inspect the ribbon cable or harness connecting it to the main board.
  • Check for pinched, cut, or twisted wires, and for any signs of moisture or corrosion.
  • Unplug and replug all connectors between the display and main board several times to clean contacts.
  • Inspect both PCBs for burnt components or cracked solder joints.

Component replacement:

  • If the harness is damaged, replace it.
  • If the harness is good, replace the display PCB first, as it is usually easier and cheaper.
  • If E6 persists, the main control board is likely faulty and should be replaced by a professional.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements