AEG Airflow / Damper or Fan Failure

Freezer cold but refrigerator warm; food in fridge compartment spoils while freezer seems normal.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked air vents between freezer and fridge, Failed refrigerator evaporator fan, Iced-up air channels, Stuck air damper

How to Fix / Troubleshooting

Quick user checks:

  • Ensure vents at the back and top of the fridge compartment are not blocked by containers or packaging.
  • Verify that the temperature setting for the fridge is not set too warm.

Airflow components:

  • Press the fridge door switch and listen for the fan. If it does not run while the compressor is on, the fan motor may be faulty.
  • If you hear ice cracking or see frost around vents, unplug the unit and perform a full manual defrost to clear ice from ducts.
  • Access the air damper (usually at the top rear of the fridge) and check for obstruction or broken gears. Replace the damper if it does not move freely.

After repair: Restore power and allow 12–24 hours for temperatures to stabilize.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Refrigerator Evaporator Fan Motor
Check Price on Amazon