dO
Amana
Door Open or Door Switch Fault
Display shows dO or DO and an audible alarm sounds; refrigerator reports door open even when door is closed.
Advertisements
Possible Causes
Door not fully closed, Misaligned door, Failed door switch, Damaged door gasket
How to Fix / Troubleshooting
Safety first: You can test the door switch with power on, but unplug the unit before removing switch assemblies.
- Confirm door closure: Open and firmly close each door. Check for items sticking out of bins or shelves that may prevent full closure.
- Inspect gasket: Look for tears, gaps, or warped sections of the door gasket. Clean gasket with warm soapy water and dry to improve sealing.
- Test door switch: Locate the door switch plunger near the top or side frame. Press it in and out; the interior light should turn on/off. If the light stays on or off regardless of switch position, the switch or wiring is faulty.
- Replace door switch (if faulty):
- Unplug the refrigerator.
- Pry the switch out gently with a plastic putty knife.
- Disconnect the wiring harness connector.
- Connect the new switch and snap it back into place.
- Check door alignment: If the door is sagging, adjust the hinge screws slightly while supporting the door to ensure proper contact with the switch.
Advertisements
Repair Difficulty
Easy
2/5
Advertisements