E5
Amana Ice Maker or Ice Compartment Sensor Error

Display shows E5; ice maker or ice compartment temperature may be incorrect, causing poor ice production.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed ice box thermistor, Loose sensor connection, Damaged harness in door or cabinet, Control board sensor input fault

How to Fix / Troubleshooting

Safety first: Unplug the refrigerator before accessing ice compartment panels or door wiring.

  • Locate ice compartment sensor: On models with a separate ice box, the thermistor is usually behind the ice compartment cover or near the ice maker housing.
  • Inspect wiring: Check for pinched or broken wires, especially where they pass through the door hinge area.
  • Test thermistor: Disconnect and measure resistance at room temperature. Compare to spec; replace if out of range.
  • Check connectors: Ensure all plugs at the control board and ice compartment are fully seated.
  • Replace sensor or harness: If the sensor is faulty, install a new one. If wiring is damaged, replace the harness section as available.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Ice Compartment Thermistor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements