F2
Amica Freezer Compartment Sensor Range/Performance Fault

Display shows F2; freezer temperature control erratic or incorrect

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Sensor out of calibration, Sensor not in correct position on evaporator, Damaged sensor insulation, Control board misreading sensor

How to Fix / Troubleshooting

Safety: Unplug the appliance before removing freezer panels.

Procedure:

  • 1. Access the freezer sensor: Remove drawers and the rear inner panel to expose the evaporator and sensor.
  • 2. Verify placement: Ensure the sensor is clipped where the manufacturer intended (usually mid-coil). If it has slipped away from the coil, reattach it.
  • 3. Inspect wiring and insulation: Check that the sensor lead is not damaged or touching heater elements. Replace if insulation is cracked or melted.
  • 4. Replace sensor: If F2 persists or the sensor shows abnormal resistance, install a new freezer sensor.
  • 5. Control board: Continued F2 after sensor replacement suggests a control board issue; seek professional service.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Freezer Compartment NTC Temperature Sensor
Check Price on Amazon