Amica Sealed System Inefficiency / Refrigerant Loss

Refrigerator and/or freezer too warm; compressor runs constantly but cannot reach set temperature

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Refrigerant leak, Partially blocked capillary tube, Weak compressor, Severely dirty condenser coils

How to Fix / Troubleshooting

Safety: Unplug the appliance before cleaning or inspecting the rear. Sealed system repairs must be done by licensed technicians.

Steps:

  • 1. Clean condenser: Pull the fridge away from the wall and vacuum dust from the condenser coils and fan. Poor heat rejection can mimic sealed system faults.
  • 2. Check door seals: Ensure gaskets seal all around and doors are not warped.
  • 3. Temperature test: After cleaning, allow 24 hours. If the compressor runs almost nonstop and the freezer cannot reach about -18 °C, a sealed system issue is likely.
  • 4. Professional service: Do not attempt to recharge refrigerant yourself. Contact an authorized refrigeration technician to check for leaks, restrictions, or compressor failure.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements