Bauknecht Airflow Imbalance Between Compartments

Freezer cold but refrigerator warm, no error code shown

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Evaporator fan not running, Air damper stuck closed, Ice blocking air channels, Return air vents blocked by food

How to Fix / Troubleshooting

Safety first: Disconnect power before removing internal panels.

  • Check for blocked vents: Move food away from vents in both fridge and freezer. Ensure air can circulate freely.
  • Listen for fan: With the freezer door open, press the door switch. You should hear the evaporator fan. If not, it may be faulty or iced over.
  • Inspect for frost: If the freezer rear wall is heavily frosted, perform a full manual defrost (12–24 hours unplugged) and then monitor.
  • Access fan and damper: If the problem returns quickly, remove the freezer rear panel to inspect the fan and air passages. Clear any ice and ensure the fan spins freely.
  • Replace failed components: If the fan motor is not operating or the damper is broken, replace the defective part.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.