E0
Beko General Control System Fault

Display shows E0 and refrigerator may not cool correctly or may behave erratically.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Control board firmware glitch,Loose wiring harness connection,Power surge affecting main PCB,Faulty main control board

How to Fix / Troubleshooting

Safety first: Unplug the refrigerator from the wall outlet before removing any panels. Do not work on live circuits.

Step-by-step:

  • Power reset: Unplug the fridge for 5–10 minutes. This can clear temporary control glitches. Plug back in and check if E0 returns.
  • Check power quality: Ensure the outlet is properly grounded and not shared with heavy appliances (microwave, dishwasher). Avoid extension cords.
  • Inspect rear connections: Pull the unit out carefully. Remove the rear lower service cover (usually a few screws). Check the main control board wiring harnesses for loose or partially seated plugs. Reseat each connector firmly.
  • Look for board damage: With power still disconnected, visually inspect the PCB for burn marks, swollen capacitors, or corrosion. If present, the board likely needs replacement.
  • Restore power and test: Refit the cover, plug the unit back in, and monitor for 10–15 minutes. If E0 reappears or cooling is unstable, the main PCB may require replacement by a qualified technician.

When to stop: If you smell burning, see arcing, or the breaker trips, disconnect power immediately and contact a professional.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board (PCB)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements