E13
Beko Overheating or High Temperature Protection Fault

Display shows E13 and the refrigerator may not cool or may shut down unexpectedly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked condenser coils,Failed condenser fan,Refrigerator installed too close to wall or in enclosed space,Faulty temperature protection sensor or control board

How to Fix / Troubleshooting

Safety first: Unplug the refrigerator before cleaning or accessing the rear.

Step-by-step:

  • Check installation: Ensure there is adequate clearance around the fridge (typically at least a few centimeters at sides and back, and space above) for ventilation.
  • Clean condenser: Remove the rear lower cover. Vacuum and brush dust from the condenser coils thoroughly.
  • Verify condenser fan: Confirm the fan is clean and spins freely. Replace if seized or noisy.
  • Allow cool-down: Leave the fridge unplugged for 30–60 minutes to cool internal components, then reconnect and monitor.

Note: If E13 returns quickly despite good airflow and a working fan, an internal sensor or the control board may be faulty and should be checked by a technician.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Condenser Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements