Belling
Compressor Start Failure
Clicking noise and compressor fails to start.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty start relay or overload, Seized compressor, Low voltage supply
How to Fix / Troubleshooting
Safety first: Unplug the refrigerator before accessing the compressor area.
Steps to address clicking:
- 1. Confirm noise source: Ensure the clicking is from the compressor start device, not from relays on the control board.
- 2. Replace start relay/overload: Remove the start device from the compressor and install a new Belling-compatible assembly.
- 3. Test operation: Restore power and listen. If the compressor still fails to start and clicks repeatedly, the compressor may be seized.
- 4. Professional service: A seized compressor requires replacement by a licensed refrigeration technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Compressor Start Relay / Overload Protector
Check Price on Amazon