E13
Belling Defrost Timer / Defrost Control Circuit Error

E13 is displayed and the refrigerator may not defrost or may show erratic temperature readings.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective electronic defrost control on PCB, Stuck defrost relay, Firmware logic error, Wiring fault in defrost control circuit

How to Fix / Troubleshooting

Safety first: Unplug the refrigerator before working on the control board or defrost wiring.

Steps to address E13:

  • 1. Manual defrost: Turn off and defrost the unit fully to restore airflow and cooling temporarily.
  • 2. Force defrost test (for advanced users): Some models allow entering a service mode to force a defrost cycle. Refer to service documentation; if the heater does not energize, suspect control or heater circuit.
  • 3. Inspect control board: Check for signs of overheating around the defrost relay area on the PCB.
  • 4. Verify heater and thermostat: Before condemning the board, ensure the defrost heater and thermostat are functional (see E4 procedure).
  • 5. Replace control board if necessary: If the heater circuit is good but the board never supplies power, replace the main PCB.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements