E14
Belling
User Interface / Display Panel Fault
E14 appears and the refrigerator may not respond correctly to temperature setting changes.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed touchpad or buttons, Damaged display PCB, Loose ribbon cable to main board, Moisture ingress into control panel
How to Fix / Troubleshooting
Safety first: Unplug the appliance before removing the display or control panel.
Steps to address E14:
- 1. Power reset: Disconnect power for 10 minutes and reconnect. Sometimes the UI will recover from a temporary glitch.
- 2. Inspect the control panel: Remove the trim and gently pull the display panel forward. Check for moisture, corrosion, or cracked PCB.
- 3. Check ribbon cable: Ensure the ribbon or harness between the UI and main board is fully seated and not damaged.
- 4. Dry moisture: If condensation is present, dry the area thoroughly and identify any air leaks around the panel that may need sealing.
- 5. Replace the UI board: If buttons or touch areas are unresponsive and E14 persists, replace the Belling-compatible user interface/display module.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
User Interface / Display Board
Check Price on Amazon
We may earn a commission from links on this page.