E6
Belling Communication Error Between Display Board and Main Control Board

Refrigerator display shows E6 and the compressor may not start or may run erratically.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose or damaged communication harness, Oxidized connectors, Faulty display/control panel, Faulty main PCB

How to Fix / Troubleshooting

Safety first: Unplug the refrigerator before removing any control covers.

Steps to address E6:

  • 1. Power cycle: Disconnect power for 10–15 minutes, then reconnect. Sometimes communication errors clear after a full reset.
  • 2. Access control boards: Remove the top control housing or rear PCB cover (depending on model). Take care not to damage plastic clips.
  • 3. Inspect wiring harness: Locate the multi-core cable linking the display/control panel to the main PCB. Check for pinched, cut, or burnt wires.
  • 4. Reseat connectors: Gently unplug and replug the connectors at both ends of the harness. Ensure they latch fully and pins are not bent or corroded.
  • 5. Check for moisture: Look for signs of condensation or liquid ingress around the display panel. If present, dry thoroughly and identify the source of moisture (e.g., door gasket leaks).
  • 6. Replace suspect board or harness: If the harness is damaged, replace it. If E6 persists and wiring is sound, either the display board or main PCB may be defective. Board-level diagnosis is best left to a professional.

Note: Do not attempt to repair PCBs at component level unless you are qualified; replacement is the usual remedy.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements