Belling
Short Cycling / Compressor Protection
Refrigerator short cycles – compressor starts and stops frequently within a few minutes.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty compressor start relay, Overheating compressor, Incorrect thermostat or sensor readings, Power supply fluctuations
How to Fix / Troubleshooting
Safety first: Unplug the appliance before accessing the compressor compartment.
Steps to address short cycling:
- 1. Verify room temperature: Extremely high ambient temperatures can cause frequent cycling. Improve ventilation or move the unit if necessary.
- 2. Clean condenser and check fan: Dirty coils or a failed condenser fan can overheat the compressor, causing it to trip on overload.
- 3. Inspect start relay/overload: Remove and inspect the compressor start device. Replace if it shows signs of burning or rattles when shaken.
- 4. Check voltage (for professionals): Low or unstable mains voltage can cause short cycling. An electrician may need to investigate.
- 5. If unresolved: A failing compressor or control board may be at fault. Contact a refrigeration technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Compressor Start Relay / Overload Protector
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements