dr
Blomberg Door Open Alarm / Door Switch Misread

Display shows dr or door icon and an alarm sounds even when the door appears closed.

Advertisements

Possible Causes

Door not fully closed, Obstruction preventing seal, Misaligned door, Faulty door switch or sensor

How to Fix / Troubleshooting

Check door closure:

  • Inspect for food packages or shelves preventing the door from closing fully.
  • Ensure the unit is level so the door can swing closed properly.

Inspect gasket:

  • Check the door gasket for tears, warping, or debris. Clean with warm soapy water and dry.

Door switch:

  • Locate the door switch and press it manually; if the alarm does not stop or the light does not change, the switch may be faulty and should be replaced.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch