E7
Blomberg
Door Switch / Door Sensor Fault
Refrigerator shows E7 and may not respond correctly to door openings (lights or fans not behaving as expected).
Advertisements
Possible Causes
Failed door switch, Misaligned door magnet (for reed or Hall sensors), Broken wiring in door harness, Faulty input on control board
How to Fix / Troubleshooting
Safety first: Disconnect power before removing switch assemblies.
Check door switch operation:
- Open the door and locate the door switch (usually near the top or side frame).
- Press the switch manually and observe if the interior light turns on/off (with power on, if safe). If there is no response, the switch may be faulty.
Inspect and reseat:
- Unplug the unit, gently pry out the switch using a flat tool wrapped in tape to avoid scratching.
- Check the connector for looseness or corrosion and reseat it.
Replacement:
- If the switch feels loose, sticks, or fails continuity testing (if you have a meter), replace it with the correct Blomberg part.
Note: For models using magnetic door sensors, ensure the door gasket and magnet strip are intact and the door closes fully. Misalignment can cause E7 without a bad switch.