Blomberg Airflow Restriction Between Freezer and Refrigerator

Freezer cold but refrigerator section warm, food spoiling in fresh food compartment.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Evaporator fan not running, Air vents blocked by food, Damper door stuck closed, Heavy frost on evaporator blocking airflow

How to Fix / Troubleshooting

Quick checks:

  • Ensure air vents at the back and sides of the refrigerator compartment are not blocked by containers or bags.
  • Listen for the evaporator fan in the freezer; it should run when the compressor is on and the door switch is pressed.

Inspect for frost:

  • If the freezer back wall is covered in thick frost, the defrost system may have failed. Perform a full manual defrost (unplug 12–24 hours) to restore airflow temporarily.

Damper door:

  • Locate the air damper between freezer and fridge (often behind a cover in the fridge section).
  • Check if it opens/closes when temperature is adjusted. A stuck or broken damper will need replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Air Damper Assembly
Check Price on Amazon