E09
Bosch Door Open or Door Switch Fault

Alarm beeping, high temperature warning, E09 displayed

Advertisements

Possible Causes

Defective door switch, Misaligned door not closing fully, Damaged or dirty door gasket, Faulty door sensor magnet (on some models)

How to Fix / Troubleshooting

Safety first: Work with the unit unplugged when adjusting doors or replacing switches.

Steps:

  • Check door closure: Ensure no containers or shelves are preventing the door from closing fully. Look for warped shelves or oversized items.
  • Inspect gaskets: Examine door seals for tears, gaps, or debris. Clean with warm soapy water and dry thoroughly. Use the paper test: close the door on a sheet of paper; you should feel resistance when pulling it out.
  • Test door switch: Locate the door switch (usually in the frame). Press it in and out; the interior light should turn on/off. If not, the switch may be faulty.
  • Replace switch if needed: Pry out or unscrew the switch, disconnect the wires, and install a new Bosch-compatible switch, reconnecting wires in the same orientation.
  • Check door alignment: If the door sags or rubs, adjust the hinge screws slightly to level the door so it seals properly.

Note: If the physical switch and gasket are fine but E09 persists, the control board's door input circuit may be defective and require service.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch
Check Price on Amazon

We may earn a commission from links on this page.