E12
Bosch Refrigerator Compartment Fan Fault

Refrigerator compartment fan noise or no airflow, E12 error

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed fresh food fan motor, Ice or debris blocking fan, Damaged fan blades, Faulty fan wiring or control output

How to Fix / Troubleshooting

Safety first: Disconnect power before removing interior panels.

Steps:

  • Check airflow: Place your hand near the air vents in the fridge compartment. Weak or no airflow while the unit is running suggests a fan issue.
  • Access fan: Remove shelves and the rear interior panel of the fridge compartment to expose the fan assembly.
  • Inspect for obstructions: Look for ice buildup, packaging, or debris interfering with the fan. Clear any obstructions carefully.
  • Test fan movement: Spin the blades by hand. If stiff, noisy, or wobbly, replace the fan motor assembly.
  • Check wiring: Verify the fan connector is fully seated and wires are intact.

After repair: Reassemble panels, restore power, and confirm that airflow has returned and the E12 code clears after a power reset.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Refrigerator Evaporator Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements