E17
Brandt Multiple Sensor Correlation Error

E17 displayed and the refrigerator may show incorrect temperature readings or fail to adjust cooling properly

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

One or more thermistors out of calibration, Poor sensor placement, Control board ADC fault

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing sensors or the control board.

Step 1 – Verify actual temperatures:

  • Place a reliable thermometer in the refrigerator and freezer compartments.
  • Compare actual temperatures to the displayed values.

Step 2 – Check all thermistors:

  • Individually test refrigerator, freezer, evaporator, and ambient sensors as described in earlier steps (E1–E3, E7).
  • Replace any sensor with abnormal resistance readings.

Step 3 – Inspect control board:

  • If all sensors test correctly but E17 persists, the analog‑to‑digital converter or related circuitry on the main PCB may be faulty.
  • Replace the main control board if necessary.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Temperature Sensors Set
Check Price on Amazon