E17
Brandt
Multiple Sensor Correlation Error
E17 displayed and the refrigerator may show incorrect temperature readings or fail to adjust cooling properly
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
One or more thermistors out of calibration, Poor sensor placement, Control board ADC fault
How to Fix / Troubleshooting
Safety first: Disconnect power before accessing sensors or the control board.
Step 1 – Verify actual temperatures:
- Place a reliable thermometer in the refrigerator and freezer compartments.
- Compare actual temperatures to the displayed values.
Step 2 – Check all thermistors:
- Individually test refrigerator, freezer, evaporator, and ambient sensors as described in earlier steps (E1–E3, E7).
- Replace any sensor with abnormal resistance readings.
Step 3 – Inspect control board:
- If all sensors test correctly but E17 persists, the analog‑to‑digital converter or related circuitry on the main PCB may be faulty.
- Replace the main control board if necessary.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Temperature Sensors Set
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements