E7
Cecotec Ambient Temperature Sensor Failure

Display shows E7 and the ambient temperature reading is incorrect or dashes are shown.

Advertisements

Possible Causes

Failed ambient NTC sensor (often in front grille or control housing), Disconnected or damaged sensor wiring, Corroded connector at main control board, Main control board sensor input failure

How to Fix / Troubleshooting

Safety: Disconnect power before accessing control housings or wiring.

  • Locate ambient sensor: On many Cecotec refrigerators, the ambient sensor is located near the front grille, behind the control panel, or in the top hinge area.
  • Inspect sensor: Check for physical damage, dirt, or corrosion. Clean gently with a dry cloth if dirty.
  • Check wiring and connector: Ensure the sensor harness is intact and the connector at the control board is fully seated.
  • Replace sensor if needed: If the sensor is open/shorted or visibly damaged, install a Cecotec-compatible ambient NTC sensor.
  • Test: Restore power and verify that the ambient temperature displays correctly and E7 disappears.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Ambient NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.