Crosley
Sealed System Refrigerant Loss or Restriction
Refrigerator and freezer are warm, but compressor and fans are running continuously.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Refrigerant leak in evaporator or condenser, Blocked capillary tube, Weak compressor, Internal system contamination
How to Fix / Troubleshooting
Safety: Do not attempt to open the sealed refrigeration system yourself. Specialized tools and EPA certification are required.
Steps (owner-level checks):
- Check condenser coils: Ensure coils are clean and condenser fan is running. Dirty coils can mimic sealed-system problems.
- Inspect frost pattern: Remove the freezer rear panel. A normal system shows a light, even frost across most of the evaporator. A sealed-system issue often shows only a small patch of frost or no frost at all.
- Listen and feel: The compressor may be hot and running constantly with little cooling effect.
- Call a professional: If sealed-system failure is suspected, contact a qualified refrigeration technician. Repair may involve leak detection, brazing, evacuation, and recharging, or compressor replacement.
Advertisements
Repair Difficulty
Professional Required
5/5