ER 39
Dacor
Ice Maker Sensor / Heater Error
Display shows ER 39, ice maker may not harvest ice or may stop mid-cycle.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed ice maker mold heater, Faulty ice level or temperature sensor, Loose ice maker harness, Ice maker module failure
How to Fix / Troubleshooting
Safety: Unplug the refrigerator before servicing the ice maker.
This code indicates a problem with the ice maker's internal components.
- Reset ice maker: Turn the ice maker power switch off for 30 seconds, then back on. Some Dacor models have a test button; press and hold to initiate a test cycle if available.
- Inspect wiring: Remove the ice maker cover and check the harness connection to the ice maker module.
- Check for ice jams: Ensure no cubes are jammed in the ejector blades or mold.
- Replace ice maker assembly: If ER 39 persists and the ice maker does not complete a test cycle, replace the complete ice maker assembly.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Ice Maker Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements