E2
Danby Freezer Compartment Thermistor Failure

Digital Danby refrigerator displays E2 and freezer temperature is not stable.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed freezer thermistor, loose thermistor connector, damaged wiring harness to control board, defective main control board

How to Fix / Troubleshooting

Safety: Disconnect power before accessing internal components.

Steps to diagnose E2:

  • Reset attempt: Unplug the refrigerator for 5–10 minutes, then reconnect. If E2 reappears, proceed with checks.
  • Locate the freezer thermistor: Typically mounted on the freezer rear wall, clipped to the evaporator cover, or behind a small plastic cover near the evaporator coils.
  • Visual inspection: Look for ice buildup around the sensor, broken insulation, or disconnected plugs. Carefully remove any heavy frost with a hair dryer on low (do not overheat plastic parts).
  • Test the thermistor: Remove the thermistor from the circuit and measure resistance at room temperature. Compare to expected NTC values (commonly 5–10 kΩ at 25°C). If reading is open, shorted, or far off spec, replace it.
  • Check wiring: Trace the thermistor wires to the main control board. Look for pinched, cut, or corroded wires. Repair or replace as needed.
  • Replace parts as needed: Install a new OEM Danby freezer thermistor if faulty. If the thermistor and wiring are good but E2 persists, the main control board is likely at fault and may need replacement by a technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Freezer Compartment Thermistor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements