E7
De Dietrich
Compressor Start/Drive Circuit Fault
Display shows E7 and the compressor does not start or runs only for a few seconds before stopping.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed compressor start relay or PTC, Defective inverter module (on inverter models), Open or shorted compressor windings, Faulty main control board output
How to Fix / Troubleshooting
Safety first: Unplug the refrigerator. Work only if you are comfortable around mains voltage and sealed refrigeration components. Do not open the sealed system.
Steps:
- 1. Listen and observe: When powered, you may hear a click from the relay and then a hum followed by another click. Repeated clicking without running suggests a start issue.
- 2. Access the compressor compartment: Remove the rear lower cover to expose the compressor, start device, and main PCB/inverter.
- 3. Inspect the start relay/PTC: On non-inverter models, unplug the start device from the compressor terminals and check for signs of burning or rattling. Replace if damaged.
- 4. Test compressor windings: With the unit unplugged and start device removed, measure resistance between the three compressor pins. You should see low but non-zero resistances and no continuity to ground. If windings are open or shorted to ground, the compressor is faulty and requires professional replacement.
- 5. Inverter models: If your De Dietrich uses an inverter, check the inverter module for burnt components or smell. Replacement of the inverter should be done by a technician.
- 6. Check wiring and PCB: Verify that the harness from the PCB to the compressor/start device is intact. If all hardware checks out, the main PCB may not be commanding the compressor correctly.
- 7. Do not attempt sealed system repairs: If the compressor itself is defective, contact an authorized service center for replacement and recharging.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Compressor Start Relay / PTC
Check Price on Amazon
We may earn a commission from links on this page.