EA
De Dietrich
Water Inlet Valve or Flow Sensor Fault
Error EA on display; water dispenser does not operate or stops mid-flow.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective water inlet valve coil, Blocked water filter or inlet, Failed flow meter/flow sensor, Wiring fault between valve and PCB
How to Fix / Troubleshooting
Safety first: Unplug the refrigerator and close the water supply valve before disconnecting any water lines.
Steps:
- 1. Check water supply: Ensure the household shutoff valve is fully open and the supply hose is not kinked.
- 2. Replace or bypass the water filter: A clogged filter can trigger flow errors. Install a new genuine De Dietrich filter or temporarily bypass to test.
- 3. Access the water inlet valve: Usually located at the rear bottom of the refrigerator. Remove the rear cover to expose it.
- 4. Test valve coils: Disconnect the electrical connectors and measure coil resistance. Open or shorted coils indicate a bad valve.
- 5. Inspect the flow sensor: Some models integrate a flow meter in the valve assembly or filter head. Check for stuck turbine or damaged wiring.
- 6. Replace faulty components: Install a new water inlet valve or filter head/flow sensor assembly as required. Use new seals and tighten fittings securely, then check for leaks.
- 7. Restore water and power: Turn on the water, plug in the unit, and purge air from the system by dispensing water for several minutes.