De Dietrich
Control or Sensor Instability
Refrigerator cycles on and off very frequently (short cycling).
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Temperature sensor located too close to cold air outlet, Oversensitive thermostat settings, Main PCB hysteresis parameters incorrect, Poor door sealing causing rapid temperature swings
How to Fix / Troubleshooting
Safety first: Unplug the refrigerator before moving sensors or accessing the control board.
Steps:
- 1. Check door seals: Ensure gaskets seal properly and doors are not frequently opened unnecessarily.
- 2. Verify sensor placement: Make sure the refrigerator NTC is not directly in the cold air stream; reposition if necessary according to service instructions.
- 3. Reset controls: Return temperature settings to factory defaults and disable any special modes.
- 4. If short cycling persists: The control board may require reprogramming or replacement by a technician.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Refrigerator Compartment NTC Temperature Sensor