Etna
Door Switch Stuck or Misaligned
Interior light stays on when the door is closed, causing heat and possible melting near the light area.
Advertisements
Possible Causes
Faulty mechanical door switch, Misaligned door causing switch not to depress, Broken switch housing, Wiring short keeping light circuit energized
How to Fix / Troubleshooting
Safety first: Unplug the refrigerator before working on the light or switch.
Steps:
- Confirm symptom: Close the door slowly and look through the gasket gap to see if the light turns off. If it stays on, the switch is not being actuated.
- Inspect door alignment: Check that the door closes evenly and that hinges are not sagging. Adjust the door or leveling feet if needed.
- Test door switch: Locate the door switch (usually in the frame). Press it by hand; the light should turn off. If not, the switch may be faulty.
- Replace switch: Pry out or unscrew the switch, disconnect the wires, and install a new Etna door switch. Ensure it protrudes enough to be pressed by the door.
- Re-test: Restore power and verify that the light now turns off when the door is closed.
Advertisements
Repair Difficulty
Easy
2/5