E16
Fagor
Thermostat / Temperature Control Failure (Mechanical or Electronic)
Error code E16 appears and the refrigerator may overcool or undercool, with erratic compressor cycling.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty electronic thermostat on main PCB, Defective mechanical thermostat (on older Fagor models), Shorted or open temperature sensing circuit, Miscalibrated control firmware
How to Fix / Troubleshooting
Safety first: Disconnect mains power before accessing control components.
Steps:
- 1. Verify temperature readings: Place an accurate thermometer in both compartments and compare to the set temperatures and display readings.
- 2. Inspect control knob or panel: On mechanical models, ensure the thermostat knob is not cracked or slipping on the shaft. On electronic models, verify that changes on the panel are registered.
- 3. Access thermostat: For mechanical thermostats, remove the control housing inside the fridge and inspect the thermostat and capillary tube. For electronic models, access the main PCB and temperature control section.
- 4. Replace faulty control: If the thermostat does not switch the compressor on/off correctly or E16 persists, replace the thermostat (mechanical) or main control board (electronic) with the correct Fagor part.
- 5. Recalibrate (if applicable): Some electronic boards may require a reset or calibration procedure as per the service manual after replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Electronic Thermostat / Main Control Board
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements