E19
Fagor
Defrost Control Logic Error
Error code E19 is displayed and the refrigerator may not perform automatic defrost correctly, with intermittent fan and heater operation.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Corrupted defrost timing algorithm in main PCB, Faulty EEPROM or memory on control board, Incorrect sensor feedback due to wiring issues, Previous incorrect board replacement or configuration
How to Fix / Troubleshooting
Safety first: Disconnect mains power before accessing the control board or sensors.
Steps:
- 1. Verify sensors and heater: Before blaming the logic, confirm that the defrost sensors (NTC, thermostat) and heater are functioning and wired correctly (see E4 and E5 procedures).
- 2. Power reset: Unplug the refrigerator for at least 15 minutes to reset the control logic.
- 3. Check board part number: Ensure the installed main PCB matches the exact Fagor model. An incorrect board can cause E19.
- 4. Replace main PCB: If all defrost components are good and E19 persists, replace the main control board with the correct, updated part number. Follow any configuration steps in the service documentation.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Electronic Control Board
Check Price on Amazon
We may earn a commission from links on this page.