E7
Fagor
Main Control Board Communication / Internal Failure
Error code E7 is displayed and the refrigerator interior lights and fans may work, but the compressor does not run.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Internal failure of Fagor main electronic control board, Corrupted firmware or EEPROM on control module, Shorted low-voltage supply on PCB, Loose or oxidized multi-pin connectors on control board
How to Fix / Troubleshooting
Safety first: Disconnect the appliance from mains power before accessing the control board. Avoid touching PCB tracks with bare hands.
Procedure:
- 1. Power reset: Unplug the refrigerator for 10–15 minutes to discharge capacitors, then reconnect. If E7 reappears immediately, continue.
- 2. Access main PCB: Remove the rear cover panel (usually at the lower back) to expose the main control board housing. Remove the housing cover.
- 3. Visual inspection: Look for burnt components, bulging capacitors, or darkened areas on the PCB. Check for moisture or insect damage.
- 4. Reseat connectors: One by one, unplug and firmly reconnect all harness connectors to the board, ensuring correct orientation. Pay attention to the compressor, fan, and sensor connectors.
- 5. Check supply voltage: If you are trained and have a multimeter, verify that mains voltage is present at the board input and that the low-voltage outputs (e.g., 5 V, 12 V) are within range. Perform this only if you are competent with live testing.
- 6. Replace control board: If E7 persists and there are clear signs of board failure or no low-voltage output, replace the main control board with the exact Fagor part number. Transfer any configuration jumpers as per the service manual.
- 7. Test operation: After replacement, restore power and verify that the error clears and the compressor and fans operate normally.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Main Electronic Control Board
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements