Fagor
Short Cycling / Control Instability
Refrigerator cycles on and off very frequently (short cycling), with compressor starting and stopping every few minutes.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty temperature sensor giving unstable readings, Oversensitive thermostat placement near air outlet, Main control board relay issue, Refrigerant system imbalance causing rapid pressure changes
How to Fix / Troubleshooting
Safety first: Unplug the refrigerator before accessing sensors or control boards.
Steps:
- 1. Verify temperature stability: Use a thermometer to check if actual temperatures are stable despite frequent cycling.
- 2. Inspect sensors: Check that NTC sensors are firmly attached to their mounting points and not hanging loose in airflow. Replace any sensor with erratic resistance readings.
- 3. Control board: If sensors are good, the main control board may have a faulty relay or logic causing short cycling. Replacement may be required.
- 4. Professional check: If cycling is accompanied by unusual compressor noises, have a technician check the sealed system.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Refrigerator Compartment NTC Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.