Fagor
User Interface Failure
Refrigerator interior light works but the display and controls are unresponsive; cooling may or may not be active.
Advertisements
Possible Causes
Failed display/control PCB, Loose ribbon cable between UI and main board, Moisture damage to touch panel, Shorted keypad membrane
How to Fix / Troubleshooting
Safety first: Unplug the refrigerator before removing the control panel.
Steps:
- 1. Power reset: Disconnect power for 10 minutes, then reconnect. If the UI remains dead, continue.
- 2. Remove control panel: Carefully unclip or unscrew the front control panel. Inspect the PCB and ribbon cable.
- 3. Reseat connectors: Disconnect and reconnect the ribbon cable between the UI and main board. Check for corrosion or damage.
- 4. Replace UI PCB: If there is visible damage or no response after reseating, replace the user interface PCB with the correct Fagor part.
- 5. Test: Reassemble, restore power, and verify that buttons and display function correctly.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Display / Control Panel PCB
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements