Fagor
General Cooling Loss / Poor Refrigeration Performance
Refrigerator runs continuously and does not reach set temperature; both compartments warmer than normal.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty condenser coils reducing heat dissipation, Failed condenser fan motor, Door gaskets leaking warm air, Low refrigerant charge or weak compressor
How to Fix / Troubleshooting
Safety first: Unplug the refrigerator before cleaning coils or working at the rear.
Steps:
- 1. Clean condenser coils: Locate the condenser at the rear or underneath. Use a vacuum and soft brush to remove dust and lint thoroughly.
- 2. Check condenser fan: With the rear panel removed, verify that the condenser fan spins freely and runs when the compressor is on. Replace the fan motor if it does not run (see E14).
- 3. Inspect door seals: Close each door on a sheet of paper and pull; if it slides out easily, the gasket may be worn or misaligned. Replace damaged gaskets.
- 4. Allow time to stabilize: After cleaning and gasket checks, allow 24 hours for temperatures to stabilize. If cooling is still poor, a sealed system issue (refrigerant leak or weak compressor) is likely and requires a professional technician.