AL08
Fhiaba Power Interruption Event

Power failure or blackout alarm; display shows AL08 and may flash the highest temperature reached since the outage.

Advertisements

Possible Causes

Recent mains power outage, Loose power plug or wall outlet, Tripped circuit breaker, Faulty power cord or internal power supply board

How to Fix / Troubleshooting

Safety first: If you suspect electrical issues in the home wiring, contact a qualified electrician. Do not operate the refrigerator on damaged outlets or cords.

Step 1 – Confirm power stability:

  • Check that other appliances on the same circuit are working normally.
  • Ensure the refrigerator plug is fully inserted and the outlet is not loose.
  • Reset any tripped circuit breakers or replace blown fuses.

Step 2 – Inspect the power cord:

  • Pull the refrigerator out slightly and inspect the cord for cuts, burns, or crushed sections.
  • If the cord is damaged, unplug immediately and have it replaced by a technician.

Step 3 – Clear the alarm:

  • Use the control panel to acknowledge the AL08 alarm (usually by pressing the alarm or confirm button).
  • Check food condition, especially in the freezer, and discard items that may have thawed to unsafe temperatures.

Step 4 – Internal power supply (advanced):

  • If AL08 appears repeatedly without actual power outages, the internal power supply or control board may be misreading voltage.
  • Professional diagnosis is recommended to test the power module and replace if necessary.
Advertisements

Repair Difficulty

Easy 2/5
Advertisements