Fisher & Paykel
Sealed System Undercharge or Restriction
Refrigerator and freezer temperatures are too warm; compressor and fans run but cannot reach set temperatures.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Refrigerant leak in evaporator or condenser, Blocked capillary tube or filter-drier, Weak compressor, Internal sealed system contamination
How to Fix / Troubleshooting
Safety: Only licensed refrigeration technicians may open the sealed system. Do not attempt to add refrigerant yourself.
- Basic checks: Confirm doors close properly, gaskets seal, and condenser coils are clean. Ensure fans and compressor are running.
- Observe frost pattern: Remove the freezer rear panel and inspect the evaporator. A partial frost pattern (only a small section frosted) suggests a sealed system issue.
- Listen for gurgling: Unusual hissing or gurgling can indicate low refrigerant.
- Do not puncture lines: Never attempt to access refrigerant lines or valves without proper tools and certification.
- Professional repair: Contact a Fisher & Paykel-authorized technician to leak-check, evacuate, and recharge the system or replace the compressor/evaporator as needed.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Sealed System (Compressor / Evaporator / Condenser)
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements