Fisher & Paykel Compressor Not Running

Refrigerator not cooling at all; interior is warm in both fresh food and freezer sections, lights may still work.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed compressor inverter module, Open thermal overload on compressor, Faulty main control board, Seized compressor

How to Fix / Troubleshooting

Safety: Unplug the refrigerator before accessing the rear service area. High voltage is present near the compressor and inverter.

  • Check basic power: Confirm the outlet has power and the refrigerator plug is fully inserted. Verify that interior lights turn on when doors open.
  • Listen for operation: With the unit plugged in, listen at the back for compressor and condenser fan noise. If both are silent for more than 10–15 minutes, a start/control issue is likely.
  • Inspect rear components: Remove the rear lower cover and check for obvious signs of damage or burnt smell around the compressor and inverter module.
  • Condenser fan check: Ensure the condenser fan spins freely by hand. A seized fan can cause overheating and compressor shutdown.
  • Do not bypass safety devices: Do not attempt to bypass the inverter or overload protector. This can be dangerous and damage the sealed system.
  • Professional service: Diagnosis of compressor windings, inverter output, and sealed system pressures requires a licensed technician. Schedule service to test and replace the inverter or compressor as needed.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor Inverter Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements