Refrigerator displays H2; often associated with high temperature in the freezer or sensor fault.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Disconnect power before removing freezer panels.
Step 1: Confirm actual temperature
- Place an appliance thermometer in the freezer for at least 30 minutes.
- If the temperature is above 10°F (-12°C), there is a cooling issue.
Step 2: Check door and gasket
- Ensure the freezer door closes fully and the gasket seals all around.
- Look for frost around the door opening, indicating air leaks.
Step 3: Inspect evaporator and fan
- Remove the rear freezer panel and check for heavy frost blocking the evaporator.
- Listen for the evaporator fan; if it is not running while the compressor is on, test and replace the fan motor.
Step 4: Test freezer thermistor
- Test the thermistor resistance and replace if out of specification.
When to call a technician: If the evaporator has only a small frost patch or none at all, there may be a sealed system problem (low refrigerant, weak compressor) that requires a licensed technician.
Repair Difficulty
Required Part