HI
Frigidaire
High Temperature Alarm
Display shows HI for freezer or refrigerator; audible alarm may sound, indicating high temperature condition.
Advertisements
Possible Causes
Door left open, Heavy warm food load, Failed condenser fan motor, Dirty condenser coils, Faulty compressor or sealed system leak
How to Fix / Troubleshooting
Safety first: Unplug the refrigerator before cleaning coils or accessing the rear compartment.
Steps to address HI:
- 1. Ensure doors are closed: Check for items blocking closure and verify gaskets are sealing.
- 2. Allow recovery time: If large amounts of warm food were added, allow 24 hours for temperatures to recover.
- 3. Clean condenser coils: Pull the unit away from the wall, remove the rear lower cover, and vacuum dust from the condenser coils and fan area. Use a coil brush if needed.
- 4. Verify condenser fan operation: With power restored, confirm the condenser fan runs whenever the compressor is on. Replace the condenser fan motor if it does not run.
- 5. Monitor temperatures: If temperatures remain high despite good airflow and clean coils, a sealed system or compressor issue may exist and requires professional service.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Condenser Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.