Frigidaire Localized Overcooling / Airflow Imbalance

Food freezing in fresh food compartment, especially near back wall or top shelf.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Air damper stuck open, Thermistor out of calibration, Items placed directly in front of air vents, Incorrect temperature setting

How to Fix / Troubleshooting

Safety first: Unplug the refrigerator before accessing the damper or sensors.

Steps to prevent freezing:

  • 1. Adjust food placement: Move sensitive items (produce, beverages) away from direct airflow vents.
  • 2. Check temperature setting: Raise the fresh food temperature setting slightly and monitor.
  • 3. Inspect air damper: Remove the damper cover and ensure the air damper opens and closes. Replace if stuck open.
  • 4. Test thermistor: Verify the fresh food thermistor resistance; replace if out of spec.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Air Damper Assembly
Check Price on Amazon