Possible Causes

Stuck or broken air damper, Frost‑blocked evaporator coil, Failed evaporator fan motor, Blocked return air vents

How to Fix / Troubleshooting

Safety first: Unplug the refrigerator before removing interior panels or damper covers.

Steps to restore fresh food cooling:

  • 1. Check for blocked vents: Move food items away from the rear wall and top vents in the fresh food section.
  • 2. Inspect air damper: Locate the air damper assembly (usually between freezer and fresh food compartments). Remove its cover and check if the damper door moves when temperature is adjusted. If stuck closed or broken, replace the damper.
  • 3. Verify evaporator fan operation: Open the freezer, press the door switch, and listen for the fan. If not running, test and replace the evaporator fan motor.
  • 4. Check for frost buildup: Remove the freezer rear panel and inspect the evaporator. Heavy frost indicates a defrost problem; repair the defrost system.

After repair, allow 24 hours for temperatures to balance between compartments.