Frigidaire
Insufficient Cooling / Airflow or Sealed System Issue
Refrigerator and/or freezer not cold enough; compressor and fans run but temperatures stay high.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty condenser coils, Weak condenser fan motor, Door gasket leaks, Low refrigerant charge or inefficient compressor
How to Fix / Troubleshooting
Safety first: Unplug the refrigerator before cleaning coils or working near the compressor.
Steps to improve cooling:
- 1. Clean condenser coils: Access the coils at the rear or bottom and remove dust with a vacuum and coil brush.
- 2. Check condenser fan: Ensure the condenser fan motor spins freely and runs whenever the compressor is on. Replace if noisy or not running.
- 3. Inspect door gaskets: Look for condensation or frost around door edges, indicating leaks. Replace damaged gaskets.
- 4. Check for frost pattern: Remove the freezer rear panel and inspect the evaporator. A partial frost pattern (only a small section frosted) suggests a sealed system problem requiring a professional.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Condenser Fan Motor
Check Price on Amazon