Gaggenau
Door Alignment or Switch Issue
Door alarm sounds frequently even when doors appear closed.
Advertisements
Possible Causes
Misaligned door hinges, Warped door, Weak or damaged door gasket, Faulty door switch or magnet alignment
How to Fix / Troubleshooting
Safety: No internal electrical work is required for basic alignment, but unplug if adjusting hinges near wiring.
Steps:
- 1. Check for obstructions: Ensure shelves, bins, or tall items are not preventing the door from closing fully.
- 2. Inspect gasket contact: Look for gaps between the gasket and cabinet. Adjust contents or gasket as needed.
- 3. Adjust hinges: Use the adjustment screws on the upper and lower hinges to raise, lower, or shift the door so it closes squarely.
- 4. Verify switch operation: Press the door switch manually and confirm the alarm stops. If not, the switch or sensor may be faulty and should be replaced (see E10 entry).
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Door Hinge Assembly
Check Price on Amazon
We may earn a commission from links on this page.