E08
Gaggenau Ambient Temperature Sensor Fault

Refrigerator displays E08 and may show unusually high or low temperature readings not matching actual interior temperature.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective ambient NTC sensor, Sensor dislodged from mounting location, Damaged wiring from sensor to control board, Faulty sensor input on main control

How to Fix / Troubleshooting

Safety: Disconnect mains power before accessing any sensor wiring.

Steps:

  • 1. Confirm environment: Ensure the refrigerator is installed in an appropriate ambient temperature (typically 10–38°C). Extreme ambient conditions can affect readings but should not trigger E08 unless the sensor is faulty.
  • 2. Locate ambient sensor: On many Gaggenau models, the ambient sensor is located behind a small grille on the top or rear of the cabinet, or near the condenser area.
  • 3. Inspect sensor and wiring: Remove the grille or cover and check that the sensor is intact and its wiring is not pinched or cut. Reseat the connector.
  • 4. Test sensor resistance: With power off, disconnect the sensor and measure resistance. Compare to the expected NTC value for room temperature. Replace the sensor if readings are open, shorted, or far out of range.
  • 5. Replace sensor: Install a new ambient NTC sensor if needed, routing the wiring as originally installed.
  • 6. Control board check: If a known-good sensor is installed and E08 persists, the main control board may be defective and should be evaluated by a technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ambient NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements