E11
Gaggenau Setpoint / Control Sensor Fault (Internal Control Sensor)

Refrigerator displays E11 and may not maintain set temperatures; supercool or superfrost functions may not operate correctly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed internal control NTC sensor, Loose sensor connection on control board, Damaged harness between sensor and PCB, Faulty main control board

How to Fix / Troubleshooting

Safety: Disconnect mains power before accessing control compartments or wiring.

Procedure:

  • 1. Reset appliance: Unplug for 5–10 minutes, then restore power. If E11 reappears, continue.
  • 2. Identify control sensor: Some Gaggenau models use a dedicated sensor near the air mixing or control area to regulate setpoints. Refer to your service documentation or locate the extra NTC sensor near the air duct or control housing.
  • 3. Inspect wiring: Check that the sensor connector is firmly attached and that the harness is not damaged or pinched.
  • 4. Test sensor: With power off, disconnect the sensor and measure resistance. Compare to expected NTC values. Replace if open, shorted, or out of range.
  • 5. Replace sensor: Install a new Gaggenau-compatible control NTC sensor, routing wiring as originally installed.
  • 6. Control board check: If a new sensor does not clear E11, the main control board may be defective and should be replaced by a professional.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Control NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements