E2
GE Appliances
Freezer Thermistor Error
Diagnostic mode shows E2 and freezer temperature control is erratic or inaccurate.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open or shorted freezer thermistor, Damaged thermistor harness, Loose connector at control board, Failed control board sensor circuit
How to Fix / Troubleshooting
Safety first: Disconnect power before accessing the freezer interior panels.
- Locate freezer thermistor: Typically mounted on the rear wall or clipped to the evaporator tubing behind the rear panel.
- Inspect and test: Check for physical damage, then disconnect and measure resistance at a known temperature. Replace if out of specification.
- Verify harness and board: Trace the thermistor wires to the main board, ensuring no breaks or pinched sections. Reseat the connector at the board.
- Replace control board if needed: If wiring and thermistor are good but E2 persists, the main control board may need replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Freezer Thermistor
Check Price on Amazon