GE Profile
Insufficient Heat Exchange / Airflow Restriction
Refrigerator and/or freezer temperature too warm but compressor and fans are running.
Advertisements
Possible Causes
Dirty condenser coils, Condenser fan running slowly or intermittently, Door gaskets leaking warm air, Overpacked shelves blocking vents
How to Fix / Troubleshooting
Safety first: Unplug the refrigerator before cleaning coils or working near moving fans.
- Clean condenser: Use a coil brush and vacuum to thoroughly clean the condenser coils under or behind the unit.
- Check condenser fan: Ensure the fan spins freely and runs whenever the compressor is on. Replace if noisy or slow.
- Inspect gaskets: Look for gaps, tears, or hardened sections in door gaskets. Replace if they do not seal tightly.
- Organize contents: Keep air vents clear and avoid blocking the rear wall with large items.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Condenser Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.